ESCHERICHIA COLI COUNTING USING LENS-FREE IMAGING FOR SEPSIS DIAGNOSIS

机译:大肠埃希菌计数的无透镜成像诊断脓毒症

获取原文
获取原文并翻译 | 示例

摘要

Sepsis causes 9.3% of overall deaths in United States. To diagnose sepsis, cell/bacteria capture and culturing methods have been widely investigated in the medical field. Escherichia Coli (E. Coli) is used as a model organism for sepsis in blood stream since wide variety of antibodies are established and the genetic modification process is well documented for fluorescent tagging. In point-of-care testing applications, the sepsis diagnostics require fast monitoring, inexpensive testing, and reliable results at resource limited settings, i.e. battle field, home care for dialysis. However, the cell/E.coli are hard to directly capture and see at the POCT because of the small size, 2 μm long and 0.5 μm in diameter, and the bacteria are rare in the blood stream in sepsis. Here, we propose a novel POCT platform to image and enumerate cell/E.coli on a microfluidic surface to diagnose sepsis at resource limited conditions. We demonstrate that target cells are captured from 5 μl of whole blood using specific antibodies and E.coli are imaged using a lens-free imaging platform, 2.2 μm pixel CMOS based imaging sensor. This POCT cell/bacteria capture and enumeration approach can further be used for medical diagnostics of sepsis. We also show approaches to rapidly quantify white blood cell counts from blood which can be used to monitor immune response.
机译:败血症在美国造成9.3%的总死亡。为了诊断败血症,在医学领域已经广泛研究了细胞/细菌捕获和培养方法。大肠杆菌(E. Coli)被用作血流中败血症的模型生物,因为已建立了多种抗体,并且遗传修饰过程已被证明可以用于荧光标记。在现场护理测试应用中,败血症诊断需要在资源有限的环境下(即战场,透析家庭护理)进行快速监控,廉价的测试以及可靠的结果。但是,由于细胞小,长2μm,直径0.5μm,因此难以在POCT上直接捕获和观察到,在败血症的血流中很少见细菌。在这里,我们提出了一个新颖的POCT平台来成像和枚举微流体表面上的细胞/大肠杆菌,以在资源有限的情况下诊断败血症。我们证明使用特定抗体从5μl全血中捕获靶细胞,并使用无透镜成像平台,基于2.2μm像素CMOS的成像传感器对大肠杆菌进行成像。此POCT细胞/细菌捕获和计数方法可进一步用于败血症的医学诊断。我们还展示了从血液中快速定量白细胞计数的方法,可用于监测免疫反应。

著录项

  • 来源
    《Unmanned/unattended sensors and sensor networks VI》|2010年|P.748011.1-748011.8|共8页
  • 会议地点 Berlin(DE)
  • 作者单位

    Bio-Acoustic MEMS in Medicine (BAMM) Laboratory, HST-Center for Biomedical Engineering, Department of Medicine, Brigham and Women's Hospital, Harvard Medical School, Boston, MA USA 02139;

    rnBio-Acoustic MEMS in Medicine (BAMM) Laboratory, HST-Center for Biomedical Engineering, Department of Medicine, Brigham and Women's Hospital, Harvard Medical School, Boston, MA USA 02139;

    rnNaval Undersea Warfare Center, Division Newport, Newport, RI USA 02139;

    rnBiomedical Microdevices and Microenvironments Laboratory, Boston University College of Engineering, Department of Biomedical and Manufacturing Engineering, Boston, MA USA 02139;

    rnBio-Acoustic MEMS in Medicine (BAMM) Laboratory, HST-Center for Biomedical Engineering, Department of Medicine, Brigham and Women's Hospital, Harvard Medical School, Bost;

  • 会议组织
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 TP212;
  • 关键词

    E. coli enumeration; point-of-care sepsis diagnosis; lens-free imaging;

    机译:大肠杆菌枚举;即时护理败血症诊断;无镜头成像;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号