首页> 外文会议>Signal Processing and its Applications (CSPA), 2012 IEEE 8th International Colloquium on >The effect of functional electrical stimulation (FES) on paraplegic muscle fatigue
【24h】

The effect of functional electrical stimulation (FES) on paraplegic muscle fatigue

机译:功能性电刺激(FES)对截瘫肌疲劳的影响

获取原文
获取原文并翻译 | 示例

摘要

Stimulation trains of different combination of frequency and pulse-width can be used to generate the muscle force required to perform a functional task during functional electrical stimulation (FES). However, with repetitive activation, the muscle will fatigue and an increase in either the frequency or the pulse-width of stimulation will be required to enable the targeted muscle force to be maintained. This study compares isometric performance and paraplegic muscle fatigue using two different protocols: protocol 1 uses 5 different stimulation frequencies varying from 10Hz to 50Hz with other parameters fixed; and protocol 2 uses 5 different stimulation pulse-widths varying from 200μs to 400μs with other parameters fixed. This range is selected based on a suitable frequency and a pulse width for paraplegic. Muscle performance is assessed by measuring percent decline in peak force and maximum muscle force for different stimulation frequencies and pulse-widths. A simple rule is introduced to avoid spasm or injury to the leg during FES application. The results from this study show that higher frequency gives faster muscle fatigue and the selection of force required to perform a functional task is important for obtaining the optimum stimulation parameters. Stimulation pulse-width has no significant effect on the muscle fatigue but highly affects the maximum muscle force. The rule proposed is important and is found to be useful to avoid leg injury, spasm or uncomfortable feeling during FES application. This rule also can be used to choose optimum stimulation parameters.
机译:频率和脉冲宽度的不同组合的刺激序列可用于生成在功能性电刺激(FES)期间执行功能性任务所需的肌肉力。然而,随着重复激活,肌肉将疲劳,并且将需要增加刺激的频率或脉冲宽度以使得能够维持目标肌肉力。本研究使用两种不同的方案比较了等距性能和截瘫性肌疲劳:方案1使用5种不同的刺激频率,频率从10Hz到50Hz,其他参数固定;协议2使用5种不同的刺激脉冲宽度,范围从200μs到400μs,并且其他参数固定。根据截瘫的合适频率和脉冲宽度选择此范围。通过测量不同刺激频率和脉宽下峰值力和最大肌肉力的下降百分比来评估肌肉性能。引入了一条简单的规则,可避免在FES应用过程中腿部痉挛或受伤。这项研究的结果表明,较高的频率会使肌肉疲劳更快,而执行功能性任务所需的力选择对于获得最佳刺激参数很重要。刺激脉冲宽度对肌肉疲劳没有明显影响,但会极大地影响最大肌肉力量。建议的规则很重要,并且被发现有助于避免在FES施用过程中腿部受伤,痉挛或不适感。该规则也可用于选择最佳刺激参数。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号