A proven technology has been developed for monitoring and controlling the CMP processes involving a stop at a layer which contains nitride. This technology is based on the fact that a measurable amount of ammonia (NH_3) will be generated during the nitride polishing. The detection of ammonia is accomplished by converting ammonia to nitrogen monoxide (NO) catalytically, then reacting the NO with ozone (O_3) to form excited state nitrogen dioxide (NO_2~*) followed by detecting its light emission. The endpoint detection system is designed to analyze and to measure these very small changes of ammonia concentration within the slurry with high velocity (~ 1 sec) and accuracy (ppb). The system is already approved for BPSG and STI CMP processes on different polisher types - Ebara and SpeedFam-IPEC (Westech and Auriga C).
机译:已经开发出用于监视和控制CMP工艺的成熟技术,该工艺涉及在包含氮化物的层处停止。该技术基于以下事实:在氮化物抛光过程中将产生可测量量的氨(NH_3)。氨的检测是通过将氨催化转化为一氧化氮(NO),然后使NO与臭氧(O_3)反应形成激发态二氧化氮(NO_2〜*),然后检测其发光来完成的。终点检测系统旨在分析和测量浆液中氨浓度的微小变化,并具有较高的速度(〜1秒)和准确度(ppb)。该系统已被批准用于Ebara和SpeedFam-IPEC(Westech和Auriga C)不同抛光机类型的BPSG和STI CMP工艺。