Near infrared reflectance spectroscopy as a novel method to detect demyelination in rat sciatic nerve in-vivo

机译:近红外反射光谱法是一种检测大鼠坐骨神经离体脱髓鞘的新方法

获取原文
获取原文并翻译 | 示例

摘要

This study was done to use near infrared (NIR) spectroscopy to bring out differences in the anatomical substructures in the rat spinal cord and further to differentiate scattering between demyelinated and normal sciatic nerves in rat models, thereby exploring a new methodology to localize MS (multiple Sclerosis) lesions in vivo for animal studies. The experimental setup consisted of a tungsten light source, CCD array spectrometer, and bifurcated optical fibers for light delivery and detection of back scattered light from tissue. The measurement system was calibrated with reflectance standard. The spinal cord of 14 rats was exposed by laminectomy, and the measurements were taken on 8 points at intervals of 1 mm on the right and left lumbar-sacral regions and the central blood vessel. For measurements on the sciatic nerve, the spinal nerves of 84 rats were ligated according to the Chung Model. Measurements were taken on five points on both the ligated and the control nerve side after 1, 4, 7 and 14 days. The reduced scattering coefficient, μ_s, was found to be higher in the lumbar-sacral regions (34.17 ± 2.05 cm~(-1)) than that near the central blood vessel (19.9 ± 3.8 cm~(-1)). Statistically, there was significant difference in scattering between the control side and the ligated side on postoperative days 4, 7, and 14. This study shows a promising diagnostic value in the future for monitoring of demyelinated CNS (central nervous system) diseases, like Multiple Sclerosis.
机译:这项研究是使用近红外(NIR)光谱进行的,以揭示大鼠脊髓的解剖亚结构差异,并进一步区分大鼠模型中脱髓鞘和正常坐骨神经之间的散射,从而探索了一种定位MS的新方法(多个硬化症)体内病灶,用于动物研究。实验装置由钨光源,CCD阵列光谱仪和分叉光纤组成,用于光传输和检测来自组织的反向散射光。用反射率标准对测量系统进行校准。通过椎板切除术暴露14只大鼠的脊髓,并在左右腰lu区和中央血管上以1mm的间隔在8个点上进行测量。为了测量坐骨神经,根据Chung模型结扎了84只大鼠的脊神经。在1、4、7和14天后,在结扎侧和对照神经侧的五个点上进行测量。发现腰scattering区域的散射系数μ_s降低(34.17±2.05 cm〜(-1))高于中央血管附近的散射系数(μs)(19.9±3.8 cm〜(-1))。从统计学上讲,术后第4、7和14天,对照侧和结扎侧之间的散射存在显着差异。这项研究显示,将来在监测脱髓鞘的CNS(中枢神经系统)疾病(如多发性骨髓瘤)中具有广阔的诊断价值硬化。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号