In the 1990s in German nuclear power plants (NPPs) a system for filtered venting has been designed and upgraded under consideration of operational aspects. This system has not been designed for the earthquake load case. After the Fukushima accident the German Reactor Safety Commission (RSK) drafted recommendations regarding the robustness of the German nuclear power plants. According to this, German NPP-operators have to show that the piping and components of the filtered venting system have a sufficient resistance against earthquake and that the system still has the integrity after earthquake load case. Germany is characterized by low seismicity. Particularly for the E.ON Kernkraft GmbH (EKK)-operated nuclear power plants, the design intensity for the sites is below the intensity of I < 6.5. Because of this low intensity the robustness of the system of the filtered venting was assessed by engineering practice. This means the assessment included a combination of assessment criteria for verification by experience based considerations: Inspection walk down Review of the documentation European Macroseismic Scale 98 Observations of earthquakes in Germany International experiences regarding originally non-seismic designed piping systems under seismic action Comparison of originally non-seismic designed system-areas with the originally seismic-designed system-areas of the same nuclear power plant Comparison of the structure with the application guidelines PAR Reviewing the design calculation of the system for operating loads (positive reviewed by the authorities) By considering all the above listed criteria it can be assumed that the piping and components of the filtered venting system in EKK owned NPPs resist the design earthquake and are still integer after the earthquake.
机译:在德国核电站(NPPS)的20世纪90年代,在考虑运营方面,设计并升级了过滤通风系统。该系统尚未为地震载荷盒设计。在福岛事故发生后,德国反应堆安全委员会(RSK)起草了关于德国核电厂的稳健性的建议。据此,德国NPP运营商必须表明,过滤通风系统的管道和部件对地震具有足够的阻力,并且系统仍然在地震载荷壳后具有完整性。德国的特点是出地震性低。特别是对于E.ON Kernkraft GmbH(EKK) - operated核电站,场地的设计强度低于I <6.5的强度。由于这种低强度,通过工程实践评估了过滤通风系统的鲁棒性。这意味着评估包括基于经验的考虑因素的评估标准的组合:检验步行审查文件欧洲宏观审查98德国地震观察的国际经验有关原始非地震作用的最初非地震设计管道系统的国际经验。 - ismisismic设计的系统区域,最初的地震设计系统领域的相同核电站的结构与结构指南相同的结构,通过考虑所有审查系统的操作负荷(当局审查)的设计计算来审查系统的设计计算上面列出的标准可以假设EKK所拥有的NPP中过滤通风系统的管道和部件抵抗设计地震,并且在地震后仍然是整数。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号