The Denver Dept. of Public Health and Environment (DDPHE) has deployed and evaluated numerous low cost sensors that measure PM2.5, temperature, and relative humidity since early 2018. We have sensors collocated in triplicate at Interstate 25 Globeville(I25GLO; a USEPA near road site in an environmental justice area), one at La Casa (a USEPA NCoresite), and one at National Jewish Hospital (a PM2.5 FEM site). Low cost sensors are garnering significant interest from regulatory agencies, researchers, and community groups as a way to measure relative differences in space and time, especially for unique events like wildfires and other source specific hot spots. Denver is focusing on PM2.5 to start based on good comparisons to FRM and FEM instruments in other real world field studies. The USEPA sites at GLO and LaCasause GRIMM 180 EDM instruments to measure PM2.5, while at National Jewish Hospital a Teledyne 640 is utilized. We will present results showing sensor to sensor variability, comparison with two federal equivalent method (FEM) instruments, and comparing sensors to FEM instruments with different aerosol characteristics, i.e. near road vs residential. We will show overall bias of the sensors against the FEM instruments, seasonal variation based on temperature and humidity changes, and how we are reporting data to the community, both corrected and uncorrected. Denver will also discuss our expanding sensor network over the next several years as a result of a $1M Bloomberg Mayor's Challenge grant and how we are partnering with the local school district to make this exposure information actionable for the 10%+ of Denver Public School students affected by asthma. We also have plans to strategically deploy at least 100 more sensors throughout the city via an innovative public private partnership (P3), that will add nitrogen dioxide and/or ozone to the monitoring suite.
机译:丹佛部门的公共卫生和环境(DDPHE)部署并评估了自2018年初以来测量PM2.5,温度和相对湿度的许多低成本传感器。我们在25号州际公路(I25GLO的州际公路(I25GLO)中有三份并列的传感器。在环境司法区附近的公路站点),一个在La Casa(Umerdpa Ncoresite),一个在国家犹太医院(PM2.5 FEM站点)。低成本传感器是从监管机构,研究人员和社区团体获得重大兴趣,作为测量空间和时间的相对差异,特别是对于野火等独特事件以及其他源特定的热点。丹佛专注于PM2.5以基于对其他真实世界研究中的FRM和FEM仪器的良好比较来开始。 Glo和Lacasause Grimm 180 EDM仪器的USEPA网站用于衡量PM2.5,而在国家犹太医院使用Teledyne 640。我们将显示结果显示传感器传感器可变性的结果,与两种联邦等效方法(FEM)仪器进行比较,并将传感器与具有不同气溶胶特性的FEM仪器进行比较,即在Road VS Residentive附近。我们将向FEM仪器显示传感器的总体偏见,基于温度和湿度的变化,以及我们如何向社区报告数据,纠正和未经校正的季节性变化。丹佛还将在接下来的几年内讨论我们的扩展传感器网络,由于100万美元的彭博长市长的挑战赠款以及我们如何与当地学区合作,以使这一曝光信息可行为丹佛公立学校的10%+ + 10%+受哮喘影响。我们还计划通过创新的公共私人伙伴关系(P3)在整个城市战略地部署至少100个传感器,这将为监测套件添加二氧化氮和/或臭氧。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号