The disconnector is becoming a device with frequent failures in transformer substations, seriously affecting the safe operation of power grid. In this paper, the clamping stagnation problem of disconnector in the process of disconnecting was investigated. According to the different characteristics of motor current in varying degree of clamping stagnation, the method of mechanical fault diagnosis, on account of differences in motor current characteristics, was proposed. Specifically, the magnitude of current amplitude was used to judge the intensity of clamping stagnation, and the absolute value integral of motor current was used for distinguishing the normality and slight astringency. With the characteristics of low frequency requirement, high reliability and strong practicability, the method could be realized via microcomputer protection device. Experimental results verified its feasibility and effectiveness.
机译:隔离开关正在成为变压器变电站频繁故障的设备,严重影响电网的安全操作。本文研究了断开过程中断开器的夹紧停滞问题。根据电动机电流的不同特性,提出了机械故障诊断方法,因为电动机电流特性的差异。具体地,使用电流幅度的幅度来判断夹紧停滞的强度,并且电动机电流的绝对值积分用于区分正常性和轻微的涩味。随着低频要求的特点,高可靠性和强大的实用性,可以通过微型计算机保护装置实现该方法。实验结果验证了其可行性和有效性。