首页> 外文会议>2019 IEEE 3rd Information Technology, Networking, Electronic and Automation Control Conference >Mechanical Fault Diagnosis of High Voltage Disconnector Based on Motor Current Detection
【24h】

Mechanical Fault Diagnosis of High Voltage Disconnector Based on Motor Current Detection

机译:基于电动机电流检测的高压隔离开关机械故障诊断

获取原文
获取原文并翻译 | 示例

摘要

The disconnector is becoming a device with frequent failures in transformer substations, seriously affecting the safe operation of power grid. In this paper, the clamping stagnation problem of disconnector in the process of disconnecting was investigated. According to the different characteristics of motor current in varying degree of clamping stagnation, the method of mechanical fault diagnosis, on account of differences in motor current characteristics, was proposed. Specifically, the magnitude of current amplitude was used to judge the intensity of clamping stagnation, and the absolute value integral of motor current was used for distinguishing the normality and slight astringency. With the characteristics of low frequency requirement, high reliability and strong practicability, the method could be realized via microcomputer protection device. Experimental results verified its feasibility and effectiveness.
机译:隔离开关正在成为变电站中频繁发生故障的设备,严重影响电网的安全运行。本文研究了隔离开关在断开过程中的夹紧停滞问题。针对电机电流在不同程度的钳位停滞中的不同特性,提出了一种基于电机电流特性差异的机械故障诊断方法。具体而言,使用电流振幅的大小来判断夹持停滞的强度,并使用电动机电流的绝对值积分来区分正常性和轻微涩味。该方法具有频率要求低,可靠性高,实用性强的特点,可以通过微机保护装置来实现。实验结果证明了其可行性和有效性。