The pump shaft generally exposed either to liquids, which pumped continuously, or in certain locations along the shaft. The shaft material is Duplex Stainless Steel AISI 329H (UNS S32900). The purpose of this study is to determine the failure of the seawater pump shaft used in the engine cooling system on the ship anchor Handling Tug Supply (AHTS). Visual observation is the study of SWCP (Sea Water Cooling Pump) shaft material. The SEM test used to determine the initial crack (crack initiation). The EDS test used for chemical composition and the Brinell Hardness Tester hardness test also used to determine material hardness. Voltage analysis used to find out how much load received by the shaft. These five tests support in analyzing pump shaft failure. The conclusion of this failure analysis is that the shaft material has porosity. Fatigue cracks originate from the outer surface area of the shaft.
机译:泵轴通常暴露于液体,其连续泵送,或沿着轴的某些位置处泵送。 轴材料是双相不锈钢AISI 329H(未S32900)。 本研究的目的是确定在船锚处理拖船供应(AHTS)上发动机冷却系统中使用的海水泵轴的故障。 目视观察是SWCP(海水冷却泵)轴材料的研究。 用于确定初始裂缝(破裂启动)的SEM测试。 用于化学成分和Brinell硬度测试仪硬度测试的EDS测试也用于确定材料硬度。 电压分析用于了解轴接收的负荷。 这五项测试支持分析泵轴故障。 该故障分析的结论是轴材料具有孔隙率。 疲劳裂缝来自轴的外表面区域。