首页> 外文会议>International Conference on Performance-based Fire and Fire Protection Engineering >Influence of smoke damper configuration on point extraction ventilation system of an urban tunnel
【24h】

Influence of smoke damper configuration on point extraction ventilation system of an urban tunnel

机译:烟雾阻尼装置对城市隧道点提取通风系统的影响

获取原文

摘要

Smoke poses a great risk to people in a tunnel fire if not controlled effectively, so how to extract smoke out of tunnel is an important issue of tunnel fire protection. In this study, numerical simulation has been carried out to study the influence of smoke damper configuration on point extraction ventilation system of an urban tunnel using FDS 5.5. Six fire scenarios have been simulated with different damper configurations, and simulation results of damper flow rate, visibility and temperature distribution in the tunnel have been analyzed to evaluate the different fire cases. It can be concluded that the damper area has little influence on the fire smoke control when it is large than 3m2, but the damper number and damper spacing have much more influence on smoke control of the point extraction ventilation system of this tunnel.
机译:如果没有有效控制,烟雾会对隧道火灾的人带来很大的风险,因此如何从隧道中提取烟雾是隧道防火的重要问题。在该研究中,已经进行了数值模拟,以研究使用FDS 5.5研究城市隧道点提取通风系统对城市隧道点提取通风系统的影响。已经用不同的阻尼器配置模拟了六种火灾情景,并且已经分析了隧道中阻尼器流量,可见度和温度分布的模拟结果,以评估不同的消防案例。可以得出结论,阻尼区域在大于3m2时对火烟控制的影响几乎没有影响,但阻尼器号和阻尼器间距对该隧道点提取通风系统的烟雾控制有更多影响。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号