A study has been performed to quantify the UV dose delivery from multiple UV reactors in series. As part of this assessment, simulations were performed on open channel - reactors and closed conduit reactors that were physically placed end to end or separated by a significant number of pipe diameters or open channel widths. Simulations were also performed with microorganisms that had different UV response kinetics. Results showed that UV dose delivery from multiple reactors in series may not consistently follow the sum of the individual UV dose delivered by each reactor. The results of the numerical simulations suggest that the summation of UV dose delivery from multiple reactors in series can only be achieved when sufficient mixing is accomplished upstream from each subsequent individual reactor.
机译:已经进行了一种研究以量化来自多个UV反应器的UV剂量递送。作为该评估的一部分,在开放式通道 - 反应器和封闭的导管反应器上进行模拟,该封闭导管堆被物理放置到末端或通过大量的管道直径或开口通道宽度分离。还使用具有不同UV响应动力学的微生物进行模拟。结果表明,串联含有多种反应器的UV剂量递送可能不一致地遵循每个反应器递送的个体UV剂量的总和。数值模拟的结果表明,当从每个随后的单独反应器上游完成足够的混合时,才能依次串联含有多种反应器的UV剂量递送的总和。