In order to assess the service states of the permanent prestress of transverse prestressing bundle for the Xiangjiang Yinpenling Bridge (XYB), the permanent prestress values are measured. Appearance census of the diseases of transverse prestressing bundles for the cable-stayed part, the east and west incremental launching girder parts of the XYB are carried out. Three transverse prestressing bundles of the most serious corrosion are investigated by windowing damage inspection. The measured results and the analysis of the permanent prestress for the XYB show that the average permanent prestress of the three transverse prestressing bundles is about 300MPa to 550MPa, which do not meet the requirements of the design tension stress. It suggests that the appropriate treatment measures should be taken.
机译:为了评估湘江银行桥(XYB)横向预应力捆绑包的永久预应力的服务国,衡量了永久预应力值。 XYB的横向预应力束横向预应力束疾病的外观人口普查进行了XYB的XYB的东和西增加梁部位。通过窗口损坏检查来研究三个最严重腐蚀的三个横向预应力捆扎。测量结果和XYB永久预应力的分析表明,三个横向预应力束的平均永久预应力约为300MPa至550MPa,不符合设计张力应力的要求。它表明应采取适当的治疗措施。