首页> 外文会议>International Conference on Advanced Engineering Materials and Technology >Macro Analysis Would Like To Drop Half A Drop Of Solution
【24h】

Macro Analysis Would Like To Drop Half A Drop Of Solution

机译:宏观分析希望下降半一滴解决方案

获取原文

摘要

By strong alkali (acid) titration strong acid (alkali), alkali (acid) titration mono-weak acid (alkali), precipitation titration and coordination titration to drop by half a drop, and settling the titration error specific terms, to illustrate the macro titration analysis would like to have drop half a drop of a solution. When strong alkali titrate strong acid or monobasic weak acid, there is no need to drop half a drop. As strong acid titrate strong alkali, there is must to drop half a drop as methyl orange for indicator. But phenolphthalein as indicator, there is doesn't need to drop half a drop. Strong alkali titrate monobasic weak acid, there is no need to drop half a drop. Eriochrome Black T for indicator titrate magnesium ion with EDTA, there is must to drop half a drop. Titration of zinc by EDTA, don't need to drop half a drop. Titration chloride ion with Moore method can not drop half a drop."Is stringing out towards the end, and set the pace to slow down, or half a drop of a drip, drip, drip, to wash the bottle into a cone pure water wash the bottle with the solution came with all;;then a drop of a drip, drip until the color is changed, t Quickly close the faucet and stopped the titration. Is end point of titration. Drop by half a drop in the law is a little turn, drops hung to the solution, and heaving burette mouth, Would be tapered contact with the nozzle. Drop out of the fluid, and used to wash bottles in pure water down the titrant." This is described by many Analytical Chemistry Experiment book. It to the students the impression that all the titration analysis operation requires dropping half a drop drip with a solution. Is it? I'm on the issue under discussion.
机译:通过强碱(酸)滴定强酸强酸(碱),碱(酸)滴定单弱酸(碱),沉淀滴定和协调滴定滴下半滴,并沉降滴定误差特定术语,以说明宏观滴定分析希望下降半滴解决方案。当强碱滴定酸或单磷酸弱酸时,无需下降半滴。作为强酸滴定强的碱,必须将半滴作为甲基橙用于指示剂。但酚酞作为指标,不需要下降一半。强碱滴定酸盐单次弱酸,没有必要下降半滴。 Eriochrome Black T用于指示器滴定镁离子与EDTA,必须落下半滴。 EDTA的锌滴定,不需要下降一半。滴定氯离子与摩尔方法不能下降一半。“朝结束划出,并设定速度减慢,或滴落的半滴,滴水,滴水,将瓶子洗到锥形纯净水中用解决方案洗涤瓶子搭配;然后一滴滴水,滴落直到颜色变化,T快速关闭龙头并停止滴定。是滴定的终点。滴过法律的一半下降一点点转,掉下了溶液,滴眼液,滴水嘴,将与喷嘴锥接触。掉出液体,并用来在滴滴涕滴水中洗净瓶子。“这是由许多分析化学实验书描述的。对于学生来说,所有滴定分析操作都需要用解决方案丢弃半滴滴的印象。是吗?我正在讨论问题。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号