首页> 外文会议>International Conference on Soldering and Reliability >INVESTIGATING TESTING CONDITIONS FOR ELECTROMIGRATION EVALUATION AND EFFECT OF ADDITIVE ELEMENTS ON ELECTROMIGRATION RESISTANCE OF Sn58Bi SOLDER
【24h】

INVESTIGATING TESTING CONDITIONS FOR ELECTROMIGRATION EVALUATION AND EFFECT OF ADDITIVE ELEMENTS ON ELECTROMIGRATION RESISTANCE OF Sn58Bi SOLDER

机译:调查电迁移评估测试条件及附加元素对SN58BI焊料电迁移性的影响

获取原文

摘要

The present research systematically investigates the testing conditions for electromigration (EM) tests and compares the EM resistances of Sn58Bi (SB, in weight percent)-based solders including SB, Sn58Bi0.5Ag (SBA), and Sn58Bi0.5Ag0.1Cu0.07Ni0.01Ge (SBACNG) solders. With the contribution of a 2D Cu/solder/Cu interconnected-test structure which has been developed in our previous work, a quantity of EM tests are conducted on SB solder under various combinations of current density and temperature. The testing conditions are classified into three groups depending on three cases of experimental results, which are that the samples melted just after the current stressing beginning; that the morphological change (hillock formation) occurred after the sample being subjected to a current stressing for 10 h; and that there was no morphological change after 10 h, respectively. These results are plotted with the corresponding current density and temperature to investigate the appropriate testing conditions for EM tests. In addition, based on the melting temperature of SB solder and the investigated testing conditions under which the sample melted, the variation of temperature increase due to Joule heating with current density is estimated. Finally, we compare the EM resistances of SB, SBA and SBACNG solders under an average current density of 23 kA/cm2 and at 333 K for total of 20 hours. The EM resistances are compared via the morphological changes of the solders after current stressing. The morphological change is quantitatively investigated by measuring the ratio of the total EM-induced hillock volume to the current stressing time. As a result, SBACNG solder shows a higher EM resistance than those of SB and SBA solders. The effect of adding microelements on the EM resistance of SB solder is discussed.
机译:本研究系统地研究了电迁移(EM)试验的测试条件,并将SN58Bi(Sb,重量百分比)的EM电阻与基于Sb,Sn58Bi0.5Ag(SBA)和Sn58Bi0.5Ag0.1Cu0.07Ni0的SN58Bi(重量百分比)的抗蚀剂进行比较。 01GE(SBACNG)焊料。通过在我们之前的工作中开发的2D Cu /焊料/ Cu互连测试结构的贡献,在电流密度和温度的各种组合下,在SB焊料上进行了一定量的EM测试。根据实验结果的三种情况,测试条件分为三组,这是样品在当前强调开始后熔化;在样品经受电流胁迫10小时后发生形态变化(小丘形成);并且分别在10小时后没有形态变化。这些结果绘制了相应的电流密度和温度,以研究EM测试的适当测试条件。另外,基于Sb焊料的熔化温度和样品熔化的研究,估计具有电流密度的焦耳加热引起的温度升高的变化。最后,我们将Sb,SBA和SBACNG焊料的EM电阻比较在23ka / cm 2的平均电流密度和333k总计20小时。通过电流强调后通过焊料的形态变化进行比较EM电阻。通过测量总EM诱导的丘陵体积与电流应力时间的比率来定量研究形态学变化。结果,SBACNG焊料显示出比SB和SBA焊料更高的EM电阻。讨论了添加微量元素对Sb焊料的电阻的影响。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号