A new experimental technique was developed to directly observe the onset of shock initiation in powder mixtures contained in recovery capsules over time scales ranging from hundreds of nanoseconds to at least hundreds of milliseconds. Simultaneously with a thermocouple embedded in the test mixture to monitor bulk temperature changes, a photomultiplier tube detected light emissions produced by the reacting sample. A window/optic fiber system was developed that remained intact and did not move during the experiment. A polycarbonate window was placed into a steel recovery capsule, which was held solidly in place in a steel anvil designed to protect the fiber optic and to prevent motion of the window. Samples of as-blended 5Ti+3Si powders and ball-milled mixtures 5Ti+3Si were tested in this setup. In all experiments, a weak light emission peak was observed upon shock passage followed by much more intense light beginning a few milliseconds to a few hundreds of milliseconds later. The intense light emissions occurred at approximately the same time as a bulk temperature increase measured with the thermocouple. These results suggest that only a very small fraction of the sample was initiated by the shock.
机译:开发了一种新的实验技术,直接观察回收胶囊中含有的粉末混合物的休克发起的发作,随着时间的推移,从数百纳秒到至少数百毫秒。同时嵌入在测试混合物中的热电偶以监测体积温度变化,将光电倍增管检测到由反应样品产生的光发射。开发了一个窗口/光纤系统,该系统仍然完好无损,在实验期间没有移动。将聚碳酸酯窗口置于钢回收胶囊中,钢制胶囊固定在钢铁砧座上固定,该钢砧座设计用于保护光纤和防止窗口的运动。在该设置中测试了用作5Ti + 3SI粉末和球磨混合物5TI + 3SI的混合的样品。在所有实验中,在冲击通道时观察到弱的发光峰,然后更加强烈的灯光从几毫秒开始到几百毫秒。强烈的光排放在大致同时发生,随着热电偶测量的散装温度增加。这些结果表明,仅通过休克启动了一小部分样品。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号