Experimental measurement of the natural convection heat transfer for horizontal helicoidal pipes

机译:水平螺旋管自然对流热传递的实验测量

获取原文
获取外文期刊封面目录资料

摘要

The natural convection heat transfer coefficient for the helicoidal coils are experimentally measured and compared with those for horizontal cylinders. It is found that when the coil pitch to pipe diameter ratio is less than around 1.2, the heat transfer coefficient of the coils approaches that of a horizontal cylinder having a diameter equal to the coil diameter. For the P/d ratio greater than 1.4, the heat transfer coefficient approaches that for horizontal cylinder of diameter d. A modified characteristic, length which incorporates the tube diameter, the coil diameter, and the coil spacing, is used to define Nusselt and Rayleigh numbers. Using the proposed characteristic length, it is shown that the Nusselt number for horizontal helicoidal pipes can be determined using the available Nusselt and Rayleigh number correlation for straight horizontal cylinders in the range of the experimental and available data Ra ≤ 10{sup}5, within a maximum deviation of 15.4%.
机译:实验测量螺旋线圈的自然对流传热系数,并与水平圆筒的螺柱相比。发现线圈间距与管道直径比小于1.2时,线圈的传热系数接近具有等于线圈直径的直径的水平圆筒的热传递系数。对于高于1.4的P / D比,传热系数接近直径D的水平圆柱体。一种改进的特性,包括管直径,线圈直径和线圈间距的长度用于定义NUSELET和RAYLEIGH数。使用所提出的特征长度,示出了水平螺旋管的露珠数可以使用在实验和可用数据Ra≤10{sup} 5的范围内的直线水平圆柱体的可用Nusselt和瑞利数相关来确定最大偏差为15.4%。