Investigating the Effects of Different Constant Compression Forces on Pig Femur Bone During the Process of Spiral Oblique Long Bone Fracture

机译:螺旋斜长骨骨折过程中不同恒定压缩力对猪股骨骨骼的影响

获取原文

摘要

Spiral Oblique fractures are known to happen by a torsional force while the bone is under certain compression force. The purpose of this research is to compare the effects of two different, constant compressional forces during the process of spiral oblique fracture of pig femur bone. This experiment was performed by simulating the fracture with a Materials Testing System (MTS). An epoxy at both, the proximal and distal heads of the bone stabilized each bone. The bone will then be placed in the MTS. The different tests performed included combinations testing 500 and 750°N compressional forces, each at the 6°, 12°, and 18° per second torsional rate. Seven bones were tested for each of the torque speeds on each group (sample size, n = 7). The average angle of twist for the slow, average, and fast rates for Group 1 were 0.7590°, 0.8948°, 0.9376°, respectively. The average angle of twist for the slow, average, and fast rates for Group 2 were 1.3213°, 1.2580°, 1.7459°, respectively. The average maximum torque for the slow, average, and fast rates for Group 1 were 129.4258°, 133.6292°, 148.4509°, respectively. The average maximum torque for the slow, average, and fast rates for Group 2 were 123.0230°, 113.7802°, 135.7897°, respectively. The average angle of fracture for the slow, average, and fast rates for Group 1 were 64.1919°, 59.9131°, 66.0148°, respectively. The average angle of fracture for the slow, average, and fast rates for Group 2 were 72.9282°, 69.4060°, 71.1549°, respectively. Overall, the fractures made under 750°N were overall cleaner and with higher angles. The proof given by the comparisons between angle of twist, angle of fracture, and maximum torque offer enough evidence that a higher compression force creates an overall cleaner and stronger fracture over the spiral oblique fractures of pig femur bone.
机译:众所周知,螺旋斜骨折在骨骼处于某些压缩力下发生扭转力。本研究的目的是比较两种不同,恒定压缩力在猪股骨骨骨螺旋骨折过程中的影响。通过使用材料测试系统(MTS)模拟骨折进行该实验。两者的环氧树脂,骨的近端和远端头稳定每根骨骼。然后将骨骼放入MTS中。所执行的不同测试包括组合测试500和750°N的压缩力,每个电力在6°,12°和18°的每秒扭转速率下。针对每组上的每个扭矩速度测试七个骨头(样本大小,n = 7)。对于第1组的慢,平均和快速速率的平均扭曲角度分别为0.7590°,0.8948°,0.9376°。对于第2组缓慢,平均值和快速速率的平均扭转角分别为1.3213°,1.2580°,1.7459°。对于第1组缓慢,平均和快速速率的平均最大扭矩分别为129.4258°,分别为129.4258°,133.6292°,148.4509°。对于第2组缓慢,平均和快速速率的平均最大扭矩分别为123.0230°,113.7802°,135.7897°。对于第1组缓慢,平均值和快速速率的平均骨折角度分别为64.1919°,59.9131°,66.0148°。对于第2组缓慢,平均和慢速速率的平均骨折角度分别为72.9282°,69.4060°,71.1549°。总的来说,在750°N下方的骨折是整体净化器和更高的角度。通过扭曲角度,裂缝角和最大扭矩的比较给出的证据提供了足够的证据表明更高的压缩力在猪股骨骨的螺旋倾斜骨折上产生了整体清洁剂和更强的骨折。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号