The Performance Ratio of UK PV Microgeneration (2008-2014)

机译:英国PV微晶的性能比(2008-2014)

获取原文

摘要

The performance ratio of an ensemble of 6500 UK photovoltaic installations is reported on a monthly basis using microgeneration data collected via www.microgen-database.org.uk and global horizontal irradiance measurements from the UK Royal Meteorological Office. An adaptive interpolation algorithm is used to calculate irradiance for each installation in each calendar month. The mean monthly performance ratio for the UK ensemble is calculated to be 84% and the sum yearly value is 87%. Average minimum winter performance ratio is 72% and average peak summer performance ratio is 90%.
机译:每月使用通过通过www.microgogen-database.org.uk和来自英国皇家气象办公室的全球水平辐照度测量来报告6500英国光伏装置的集合的性能比。自适应插值算法用于计算每个日历月中每个安装的辐照度。英国集团的平均月度绩效比率计算为84%,总和年均值为87%。平均最小冬季绩效比例为72%,平均夏季夏季绩效比率为90%。