The radiation attenuation parameters such as radiation mass attenuation coeffcients (MAC), half value layer (HVL), mean free path (mfp) of boron carbide (B_4C) have been calculated at radiological x-ray energies using MCNPX (version 2.6.0) general purpose Monte Carlo code. The results obtained from MCNPX have been compared with standard XCOM data. Moreover, the obtained mass attenuation coeffcient results have been compared with ordinary concrete. Furthermore, standard deviation rates between MCNPX and XCOM were also calculated by statistical methods and a good agreement was obtained. The results showed that, present investigation can be useful for evaluation of shielding features of B_4C. It can be concluded that modeled standard geometry for present investigation can be used for shielding assessment of B_4C at radiological energy range.
机译:诸如辐射质量衰减系数(MAC),半值层(HV1),硼碳化硼(B_4C)的半值层(HV1),碳化硼(B_4C)的平均自由路径(MFP)的辐射衰减参数已经使用MCNPX(2.6.0版)计算通用蒙特卡洛代码。与标准XCOM数据进行比较了从MCNPX获得的结果。此外,与普通的混凝土进行了比较了所获得的质量衰减系数结果。此外,MCNPX与XCOM之间的标准差值也通过统计方法计算,获得了良好的协议。结果表明,目前的研究可用于评估B_4C的屏蔽特征。可以得出结论,目前研究的建模标准几何形状可用于在放射能源范围内屏蔽B_4C的评估。