首页> 外文会议>International Symposium on Mine Safety Science and Engineering >Experimental Study of Pre-splitting Blasting Enhancing Pre-drainage Rate of Low Permeability Heading Face
【24h】

Experimental Study of Pre-splitting Blasting Enhancing Pre-drainage Rate of Low Permeability Heading Face

机译:预分裂爆破的实验研究提高低渗透率标题面的排水前速率

获取原文

摘要

Taking the heading face of a coal mine as an example, the test of deep-hole pre-splitting blasting was processed. The amount of gas draining after pre-splitting was compared to the amount of direct drainage, and the effective radius of drainage was surveyed. The test results showed that the drainage rate of Ki coal seam reached 37.13%, which reduced the drainage time by 60%, 10 days after pre-splitting, and the gas desorption index exceed the standards until the fifth blasting. The drainage rate of K4 needed 12 days to reach 34.28%, which reduced the drainage time by 60%, and the gas desorption index exceed the standards when the third blasting processed. Obviously, the effect of gas drainage was improved by pre-splitting blasting. The effective drainage radius of Ki and K4 were 4.5 m and 5.2 m respectively after pre-splitting blasting.
机译:以煤矿为例,处理深孔预分裂爆破的试验。将预分裂后的气体量与直接引流的量进行比较,并调查了有效排水半径。测试结果表明,施工煤层的排水率达到37.13%,预分裂后10天减少了10%的排水时间,气体解吸指数超过标准,直至第五次爆破。 K4的排水率为12天达到34.28%,将排水时间减少60%,气体解吸指数在第三爆炸处理时超过标准。显然,通过预分裂喷砂改善了气体排水的影响。在预分裂喷砂后,Ki和K4的有效排水半径分别为4.5米和5.2米。