Electron spin resonance (ESR) studies were carried out for permeable 2mM ~(14)N-labeled deutrated 3 Methoxy carbonyl-2,2,5,5-tetramethyl-pyrrolidine-1-oxyl (MC-PROXYL) in pure water and 1mM, 2mM, 3mM, 4mM concentration of ~(14)N-labeled deutrated MC-PROXYL in 400mM concentration of liposomal solution by using a 300 MHz ESR spectrometer. The ESR parameters such as linewidth, hyperfine coupling constant, g-factor, partition parameter and permeability were reported for these samples. The line broadening was observed for the nitroxyl spin probe in the liposomal solution. The line broadening indicates that the high viscous nature of the liposomal solution. The partition parameter and permeability values indicate the maximum diffusion of nitroxyl spin probes in the bilayer lipid membranes at 2 mM concentration of nitroxyl radical. This study illustrates that ESR can be used to differentiate between the intra and extra-membrane water by loading the liposome vesicles with a lipid-permeable nitroxyl spin probe. From the ESR results, the spin probe concentration was optimized as 2mM in liposomal solution for ESR phantom studies/imaging, in vivo and in vitro experiments.
机译:电子自旋共振(ESR)研究中进行可渗透2mM的〜(14)N标记的氘代甲氧基3在纯水中和1mM的羰基 - 2,2,5,5-四甲基吡咯烷-1-氧基(MC-PROXYL) ,2mM的,3mM的,〜(14)的4mM的浓度通过使用300MHz的ESR光谱仪N-标记的氘代MC-PROXYL在脂质体溶液的浓度为400mm。据报道这些样品的ESR参数,例如线宽,超精细耦合常数,g因子,分割参数和渗透性。观察到在脂质体溶液中的硝酰自旋探头线展宽。线展宽表示该脂质体溶液的高粘稠性。分区参数和渗透率值表示在双层脂质膜在硝酰自由基的2mM的浓度的硝酰基自旋探测的最大扩散。该研究说明了ESR可以用于通过用脂质可渗透硝酰基自旋探头加载脂质体囊的内和外膜的水之间进行区分。从ESR结果,自旋探针浓度为ESR幻象研究/成像,在体内和体外实验中的脂质体溶液优化为2mM的。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号