This work describes a back-analysis for the interpretation of a serious structural failure observed in an area of the Acropolis North Circuit Wall. The failure occurred, according to the available historical and archaeological evidence, at the end of the 18th or beginning of the 19th century and it includes a) the collapse of the upper part of the Wall in the area examined (the crown of the Wall that had been constructed of architectural members of the entablature of the Old Temple of Athena), b) significant outward lean from the vertical (7 cm) of the remaining lower part (the part beneath the crown that collapsed), c) rotation of approximately lo d) systematic cracking of the outward face of the wall. For the analysis, the principles of rock mechanics were applied for simulation of the dry-masonry construction. Since the damage was primarily attributed to a strong earthquake motion, for the problem description information is drawn from a wide range of scientific specialization. The analyses comprised: 2-D FE elas-toplastic analysis, simplified (pseudostatic) spectral dynamic analysis and a rigorous 2-D time history analysis. The results are proven very satisfactory. The permanent displacement of the current crown of the wall, the rotation of the structure, the collapse of the entablature members (form T) and the systematic net of fractures at the outward side of the wall are consistently predicted. Therefore, the assumption that the damage was caused by an earthquake was also verified, limiting the termini of the event between 1785 and 1805.
机译:这项工作描述了对在卫城北路墙区域观察到的严重结构失败的回报。根据可用的历史和考古证据,在19世纪18日或开始的可用历史和考古证据的情况下发生了失败,其中包括A)在该地区的墙壁上部塌陷(墙壁的冠部已经建成了雅典娜旧寺庙的驻留殿的建筑成员),b)从垂直(7厘米)的剩余下部(冠下方的部分)的垂直(7厘米)的显着向外倾斜,C)旋转约LO d)墙体外表面的系统开裂。为分析,应用了岩石力学原理,用于模拟干式砌体施工。由于损坏主要归因于强烈的地震运动,因此对于问题描述信息来自广泛的科学专业化。分析包括:2-D FE ELAS-TOPLASTACTION分析,简化(假期)光谱动态分析和严格的2-D时间历史分析。结果被证明非常令人满意。持续预测,墙壁的电流冠的电流冠的旋转,围绕墙壁向外侧的裂缝和骨折的裂缝的塌陷。因此,还验证了损坏是由地震引起的假设,限制了1785年至1805年的活动的终点。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号