An investigation into the typology of the failures recorded on the first row (orthostate) of the Parthenon northern wall and analysis of their causes was undertaken. Systematic marble detachment was observed at the areas of the connectors. Failures were categorised and five failure modes were defined. The understanding of the structural history of the building and the design of new interventions requires the analysis of the factors that produced the observed failures, namely mechanical action or rust. The analysis undertaken was based on the simultaneous consideration of: (a) the kinematic restrictions of each block separately; (b) the applied system of deformations/displacements on each structural member; and (c) the applied system of deformations/displacements on the wall itself. Moreover, a numerical analysis was also undertaken, and some preliminary results are also reported. The effect of the marble orthotropy (mainly the position of the marble soft plane inside the block) was also studied. The main conclusion of the study is that the mechanical action of the connectors could explain the observed structural pathology, whereas rust is not a necessary condition for the structural failures to occur.
机译:对帕台农神庙北墙第一行(原州)记录的故障类型进行了调查,并分析了其原因。在连接器区域观察到大理石的系统分离。将故障分类,并定义了五个故障模式。要了解建筑物的结构历史和设计新的干预措施,需要分析产生观察到的故障的因素,即机械作用或生锈。进行分析是基于同时考虑:(a)每个区块的运动学限制; (b)在每个结构构件上应用的变形/位移系统; (c)在墙体本身上施加的变形/位移系统。此外,还进行了数值分析,并报告了一些初步结果。还研究了大理石正交各向异性的影响(主要是大理石块内部大理石软平面的位置)。该研究的主要结论是,连接器的机械作用可以解释观察到的结构病理,而生锈并不是发生结构故障的必要条件。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号