首页> 外文会议>Annual Computers in Cardiology Conference >Stability and Correlation of Electrogram Organization and Synchronization Indices during Atrial Fibrillation
【24h】

Stability and Correlation of Electrogram Organization and Synchronization Indices during Atrial Fibrillation

机译:电动纤维化期间电测组织和同步指标的稳定性和相关性

获取原文
获取外文期刊封面目录资料

摘要

In this work we perform a statistical study of organization and synchronization indices in electrogram (EGM) signals obtained during ablation surgery in patients with Atrial Fibrillation (AF). We have considered organization, synchronization and delay indices, obtaining by three different ways, spectral, cross-correlation and wavefront analysis: dominant frequency, f~D, regularity index, I~R, organization index, I~O, coherence, Γ, cross-correlation, ρ and τ, interquartile consistency, C~(IQR), normalized consistency measure, CE, and median delay μ (computed all in 10-second excerpts). We have studied their temporal and spatial stability, and the correlation between pairs of indices. We found that all organization indices are stable measures (CV<0.2) along time and a decrease in the synchronization degree with the increase of distance between electrodes.
机译:在这项工作中,我们在心房颤动患者(AF)患者中获得的电子图(EGM)信号中的组织和同步指数进行统计研究。我们已经考虑了组织,同步和延迟指数,以三种不同的方式获得,频谱,互相关和波前分析:主导频率,F〜D,规则性指数,I〜R,组织索引,I〜O,相干性,γ,互相关,ρ和τ,四分位数一致性,C〜(IQR),归一化一致性测量,CE和中值延迟μ(所有在10秒摘录中计算)。我们研究了它们的时间和空间稳定性,以及对指数的相关性。我们发现,所有组织指数都是稳定的措施(CV <0.2),随着电极之间的距离的增加,同步程度的减少。