Twenty years ago South Africa's Radioactivity Standards Laboratory (now operated by the NMISA) was the first to measure the activity of ~(55)Fe by combining the triple-to-double coincidence ratio (TDCR) liquid scintillation method with theoretical efficiency formulae. The extracted activity was however found to be consistently low by about 6percent. Due to improvements in both the counting system and analysis technique, it was decided to re-examine the method as applied at the NMISA. The latest results are presented and discussed, particularly with regard to a quantitative study into which vial type is better suited to obtaining accurate ~(55)Fe activity measurements.
机译:二十年前南非的放射性标准实验室(现为NMISA运营)是首先通过将三维双重合比(TDCR)液体闪烁法与理论效率公式组合来测量〜(55)的活性。然而,发现提取的活性始终低至6%。由于计数系统和分析技术的改进,决定重新检查在NMISA处应用的方法。提出和讨论了最新结果,特别是关于多样性研究的定量研究更适合获得精确〜(55)Fe活性测量。