Comparing Model Estimation with Measured Ammonia Emission Data for Naturally Ventilated Dairy Cattle Buildings with Slatted Floor

机译:用纸板底板测量模型估计与天然通风乳制牛建筑物的氨排放数据

获取原文

摘要

Laboratory experiments were carried out in a wind tunnel with a model of a slurry pit to investigate the characteristics of ammonia emission from dairy cattle buildings with a slatted floor. Ammonia emission at different temperatures and air velocities over the floor surface above the slurry pit was measured with uniform feces spreading and urine sprinkling on the surface daily. The data were used to improve a model for estimation of ammonia emission from dairy cattle buildings. Estimation results from the updated emission model were compared with measured data from 5 naturally ventilated dairy cattle buildings. The overall measured ammonia emission rates were in the range of 10 - 56 g/day per cow at air temperatures of 2.3 - 22.4 °C. The model simulated emission rates were in the range of 8 - 65 g/day per cow for the surveyed buildings. The average simulated ammonia emission rate was 15.6% higher than the mean measured value. An example of simulated and measured ammonia emission patterns for a 24-hour period is given.
机译:实验室实验在风隧道中进行,具有浆料坑的模型,以研究牛奶牛建筑物的氨排放的特点。在浆料坑上方的不同温度和空气速度下的氨发射,用均匀的粪便蔓延和尿液喷洒在表面上。该数据用于改进乳制牛建筑物氨排放估计模型。将更新的发射模型的估计与来自5个自然通风奶牛大楼的测量数据进行了比较。整体测量的氨排放率在2.​​3-22.4℃的空气温度下每牛的10-56克/天。模型模拟排放率为每台牛的8-65克/天为调查建筑物。平均模拟氨排放率高于平均测量值高15.6%。给出了24小时内的模拟和测量的氨排放图案的一个例子。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号