A synchronous Schlieren system for quantitative analysis of the ultrasonic field in megasonic wafer cleaning is described. We found that LSI patterns on the side of a silicon wafer opposite to the incidence of ultrasound were damaged during single-wafer cleaning. Defects were observed when ultrasound penetrated through the wafer at a certain angle of incidence. A Schlieren system with pulsed illumination synchronized to the ultrasonic phase was constructed, and the wave fronts in water around the wafer during megasonic cleaning were imaged. We found that ultrasound passed through the wafer when Lamb waves were generated in the wafer. This was confirmed with a computer simulation of the wave propagation.
机译:描述了一种用于巨型晶片清洁中超声波场的定量分析的同步思埃伦系统。我们发现,在单晶片清洁期间损坏了与超声波发生率相反的硅晶片侧面的LSI图案。当超声以一定的发射角度穿过晶片时,观察到缺陷。构造了具有与超声波相同步的脉冲照射的Schlieren系统,并在兆内清洁期间晶片周围的水中的波前沿进行成像。我们发现当在晶片中产生羊羔波时,超声波通过晶片。通过计算机模拟的波传播确认了这一点。