In JT-60U, there are three electron cyclotron emission (ECE) diagnostic systems [1], which are the Fourier transform spectrometer system [2], the 20-channel grating polychromator system [3] and the 24-channel heterodyne radiometer system [4]. The Fourier transform spectrometer system is absolutely calibrated using liquid nitrogen, and its result is used for relative calibration of the grating polychromator system and the heterodyne radiometer system. The grating polychromator system and the heterodyne radiometer system, whose temporal resolution is 20 #mu#s, are used for the measurement of electron temperature perturbations. In this paper, recent development and results of these ECE diagnostic system are described.
机译:在JT-60U中,有三种电子回旋缩感(ECE)诊断系统[1],其是傅里叶变换光谱仪系统[2],20通道光栅多彩器系统[3]和24通道外差辐射计系统[ 4]。使用液氮绝对校准傅里叶变换光谱仪系统,其结果用于光栅多铬仪系统和外差辐射计系统的相对校准。光栅多色仪系统和外差辐射计系统,其时间分辨率为20#mu#S,用于测量电子温度扰动。在本文中,描述了这些ECE诊断系统的最新发展和结果。