首页> 外文会议>International Conference on Electromagnetic Measurement >Comparison between the Ripple Technique and the Direct Calibration Method for Characterisation of Directional Devices
【24h】

Comparison between the Ripple Technique and the Direct Calibration Method for Characterisation of Directional Devices

机译:纹波技术与定向装置表征的直接校准方法的比较

获取原文

摘要

In this paper a comparison between two different methods for measurement of Directivity and Test Port Match of directional couplers and bridges is presented. One of them is scalar - the popular Ripple Technique - and the other one vectorial - the so-called Direct Calibration Method as derived by Juroshek in [1], with slight differences for the simultaneous measurement of both parameters. The two methods make use of a Vector Network Analyser (VNA) and the calibrations performed are verified against known standards. Also the uncertainty associated to both techniques is computed.
机译:本文介绍了两种不同方法与方向耦合器和桥梁的指导性和测试端口匹配的比较。其中之一是标量 - 流行的纹波技术 - 另一个矢量 - 所谓的直接校准方法是由Juroshek in [1]的所谓的直接校准方法,对两个参数同时测量的略有差异。这两种方法利用了矢量网络分析器(VNA),并验证了针对已知标准的校准。还计算了两种技术相关的不确定性。