首页> 外文会议>International Symposium for Testing and Failure Analysis >Defect Localization and Root Cause Analysis on e-Fuse Read Reliability Failure
【24h】

Defect Localization and Root Cause Analysis on e-Fuse Read Reliability Failure

机译:电子保险丝读取可靠性故障的缺陷本地化和根本原因分析

获取原文

摘要

Fault isolation is the most important step for Failure Analysis (FA), and it is closely linked with the success rate of failure mechanism finding. In this paper, we will introduce a case that hard to debug with traditional FA skills. In order to find out its root cause, several advanced techniques such as layout tracing, circuit edit and Infrared Ray-Optical Beam Induced Resistance Change (IR-OBIRCH) analysis had been applied. The circuit edit was performed following layout tracing for depositing probing pads by Focused Ion Beam (FIB). Then, IR-OBIRCH analysis with biasing on the two FIB deposited probing pads and a failure location was detected. Finally, the root cause of inter-metal layer bridge was found in subsequent physical failure analysis.
机译:故障隔离是故障分析(FA)的最重要步骤,它与故障机制的成功率密切相关。 在本文中,我们将介绍一种难以调试传统的FA技能的案例。 为了找出其根本原因,已经应用了诸如布局跟踪,电路编辑和红外光学光束诱导电阻变化(IR-Obirch)分析的几种先进技术。 在布局跟踪之后执行电路编辑,用于通过聚焦离子束(FIB)沉积探测垫。 然后,检测到两个FIB沉积探测垫上的偏置的IR-OBIRCH分析和故障位置。 最后,在随后的物理发生故障分析中发现了金属间层桥的根本原因。