首页> 外文会议>Annual International Conference of the IEEE Engineering in Medicine and Biology Society >A study on the elimination of the ECG artifact in the polysomnographic EEG and EOG using AR model
【24h】

A study on the elimination of the ECG artifact in the polysomnographic EEG and EOG using AR model

机译:使用AR模型消除多核癌EEG和EOG中的ECG伪影的研究

获取原文

摘要

We present the method of the elimination of ECG artifact from the polysomnographic EEG and EGG. The idea of this method is that the ECG-corrupted EEG segment can be detected from ECG R-wave and regarded as a missing segment. After this, we used two interpolations to recover the missing segment. One is the Lagrange polynomial interpolation and the other is the least square error AR interpolation. We also compared the AR-method with the LMS adaptive noise canceling method. Simulations show the AR-method performs better than other methods. To apply to the real EEG and EOG signals practically, we also developed the algorithm to detect whether the artifact level is high or not. If the artifact level is high, then the interpolations are applied.
机译:我们介绍了从多面一体脑电图和鸡蛋中消除ECG伪影的方法。这种方法的思想是可以从ECG R波检测到ECG损坏的EEG段并被视为丢失的段。在此之后,我们使用了两个插值来恢复丢失的段。一个是拉格朗日多项式插值,另一个是最小二乘误差AR插值。我们还将AR方法与LMS自适应噪声消除方法进行了比较。模拟显示AR-Method比其他方法更好。要实际应用于真正的EEG和EOG信号,我们还开发了该算法来检测伪影级别是否高。如果伪影级别高,则应用内插。

著录项

相似文献