首页> 外文会议>CORROSION Annual Conference and Exposition >FIELD APPLICATION OF CATHODIC PREVENTION ON REINFORCED CONCRETE STRUCTURES
【24h】

FIELD APPLICATION OF CATHODIC PREVENTION ON REINFORCED CONCRETE STRUCTURES

机译:阴极防治对钢筋混凝土结构的田间应用

获取原文

摘要

This paper illustrates the results gained during the first three years of cathodic protection application to Frejus highway viaducts in northern Italy. CP applications deal with corrosion control of chloride contaminated structures (cathodic protection application properly said) and the corrosion prevention of new non-contaminated structures, constructed with incorporated cathodic protection systems (so-called cathodic prevention). Both normal and post-tensioned structures are present: in the latter case the problems connected with the risk of hydrogen embrittlement of the tendons are discussed. The paper illustrates also the computerized system for gathering and monitoring data and the criteria adopted to evaluate and control the cathodic protection and cathodic prevention conditions as well as to avoid overprotection.
机译:本文说明了在意大利北部的Frejus高速公路高架桥的第一个阴极保护应用中获得的结果。 CP应用处理氯化物污染结构的腐蚀控制(妥善说明地说)和预防新的非污染结构的腐蚀,其构成了掺入的阴极保护系统(所谓的阴极预防)。讨论了正常和张紧的结构既是正常和张紧的结构都存在:在后一种情况下,讨论了与肌腱氢脆化风险相关的问题。本文还示出了用于收集和监测数据的计算机化系统以及采用的标准来评估和控制阴极保护和阴极预防条件,以及避免过度保护。