首页> 外文会议>International Conference on Electrical Contacts >EROSION MECHANISM OF W-Ag CONTACT MATERIAL IN THE AIR-BLAST CIRCUIT BREAKER UNDER THE SHORT-CIRCUIT CONDITIONS
【24h】

EROSION MECHANISM OF W-Ag CONTACT MATERIAL IN THE AIR-BLAST CIRCUIT BREAKER UNDER THE SHORT-CIRCUIT CONDITIONS

机译:短路条件下风吹断路器W-AG接触材料的侵蚀机理

获取原文

摘要

The paper discusses the erosion phenomena that occur in the W-Ag contact material applied in a Compact type low voltage air-blast circuit breaker (rated a.c. parameters: 30A, 500V, 50Hz). The breaking capability was tested under the conditions that simulated the short-circuit action of the breaker. In the test cycle, a short-circuit current of 19kA peak (cosΦ=O.3) was interrupted. After 3 min, it was turned on and then interrupted again. After the short-circuit test, changes in the contact surface and the structure of the contact material were examined. Based on the discussion of the results obtained and on an analysis of the physico-chemical processes involved, the paper discusses, in metallurgical terms, the possible mechanism of erosion that occur in the W-Ag contact material under the short-circuit conditions.
机译:本文讨论了在紧凑型低压空气喷砂断路器中施加的W-AG接触材料中发生的侵蚀现象(额定A.C.参数:30A,500V,50Hz)。 在模拟断路器的短路动作的条件下测试断裂能力。 在测试循环中,中断了19KA峰(COSφ= O.3)的短路电流。 3分钟后,打开并再次打断。 在短路测试之后,检查接触表面的变化和接触材料的结构。 基于对所获得的结果和涉及的物理化学过程分析的讨论,本文以冶金术语在冶金术语中讨论,在短路条件下W-AG接触材料中发生的侵蚀机制。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有