首页> 外文会议>IEEE Radiation Effects Data Workshop >Comparative analysis of low dose-rate, accelerated, and standard cobalt-60 radiation response data for a low-dropout voltage regulator and a voltage reference
【24h】

Comparative analysis of low dose-rate, accelerated, and standard cobalt-60 radiation response data for a low-dropout voltage regulator and a voltage reference

机译:低剂量率,加速和标准钴-60辐射响应数据的对比分析,用于低压差电压调节器和电压参考

获取原文

摘要

This paper presents the results of Cobalt-60 response measurements made on a low dropout voltage regulator and a shunt reference for three different radiation test conditions: low dose rate, accelerated (elevated temperature irradiation) and standard (50-300 rad(SiO{sub}2)/s). The accelerated test is shown to correlate well with the low dose rate failure of the reference but not for the failure of the regulator.
机译:本文介绍了在低压差电压调节器上进行的钴-60响应测量结果和三种不同辐射试验条件的分流参考:低剂量率,加速(升高的温度照射)和标准(50-300 rad(SIO {sub } 2)/ s)。随着参考的低剂量速率发生,而不是用于调节器的失效,将加速试验良好相关。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有