In order to simplify the manufacture and improve heat transfer performance of shell-and-tube heat exchangers (STHXs), we have invented a combined multiple shell-pass STHX with continuous helical baffles. The novel combined multiple shell-pass STHX with continuous helical baffles (NOVEL STHX) is compared with the conventional STHX with segmental baffles by Computational Fluid Dynamics (CFD) method. The numerical results show that, under the same mass flow rate M and the same overall heat transfer rate Q_m in the shell side, the overall pressure drop DP of the NOVEL STHX is lower than that of the STHX with segmental baffles by about 13%. The heat transfer rate Q_m of the NOVEL STHX is higher than that of the STHX with segmental baffles by about 6% under the same overall pressure drop DP. The NOVEL STHX might be used to replace the conventional STHX with segmental baffles in industrial applications to save energy, reduce cost and prolong service life.
机译:为了简化制造和提高壳管热交换器(STHXS)的传热性能,我们已经发明了一种具有连续螺旋挡板的组合多壳晶体STHX。通过计算流体动力学(CFD)方法将具有连续螺旋挡板(新颖STHX)的新型组合多壳PACT STHX(新颖STHX)进行比较。数值结果表明,在壳侧的相同质量流速M和相同的总传热速率Q_M下,新颖的STHX的总压降DP低于STHX的STHX,其分段挡板约为13%。新颖的STHX的传热速率Q_M高于同一总压降DP在相同的总压力下降下的节段挡板的STHX。小说的STHX可用于用工业应用中的节段挡板取代传统的STHX,以节省能源,降低成本和延长使用寿命。