首页> 外文会议>World Congress on Medical Physics and Biomedical Engineering >Monte Carlo Study of Dose Difference in Electron Conformal Therapy Planning Introduced by Bolus Material Approximation
【24h】

Monte Carlo Study of Dose Difference in Electron Conformal Therapy Planning Introduced by Bolus Material Approximation

机译:通过Bolus材料逼近引入的电子适形治疗计划剂量差异的蒙特卡洛研究

获取原文

摘要

When Monte Carlo (MC) method is used for dose calculations on a patient CT dataset, the materials in the CT images are often assigned based on the local Houndsfield units if the density threshold method is applied. In bolus electron conformal therapy (bolusECT), the bolus material, machinable wax, is therefore treated as soft tissue. This study investigates the dose errors introduced by this material misas signment. BEAMnrc was used to simulate electron beams from a Varian Trilogy accelerator. SPRRZnrc code was used to calculate stopping power ratios of tissue to wax, SPR_(wax)~(tissue), and tissue to water, SPR_(water)~(tissue), for 12 and 15 MeV electron beams. DOSXYZnrc was applied to calculate dose in a tissue phantom with the rectangular wax slabs of various thicknesses or a wedge-shaped bolus on top. The SPR_(wax)~(tissue) values for 12 and 15 MeV beams were calculated to be 0.935-0.945, while the SPR_(water)~(tissue) values were 0.990~0.991. The dose in tissue immediately under the bolus is overestimated by about 2.5% of maximum dose with the 3 cm bolus thickness if wax bolus is treated as tissue for 12 MeV beams. For 15 MeV beams, the error is about 1.4%. A left chest wall electron treatment case was simulated using wax and soft tissue as bolus materials in turn. Dose differences are observed in MC simulations if the bolus material is misassigned as tissue in bolusECT dose calculations. However, the error is mostly within clinical tolerance, especially for thin bolus regions which are more likely to be encountered in practice.
机译:当使用蒙特卡洛(MC)方法对患者CT数据集进行剂量计算时,如果应用了密度阈值方法,则通常会根据本地Houndsfield单位分配CT图像中的材料。因此在推注电子适形治疗(bolusECT)中,推注材料(可加工蜡)被视为软组织。这项研究调查了由这种物质误导引起的剂量误差。 BEAMnrc用于模拟来自Varian Trilogy加速器的电子束。 SPRRZnrc代码用于计算12和15 MeV电子束的组织与蜡,SPR_(蜡)〜(组织)和组织与水,SPR_(水)〜(组织)的停止功率比。使用DOSXYZnrc来计算组织体模中的剂量,该体模中具有各种厚度的矩形蜡板或顶部的楔形推注。计算出12和15 MeV光束的SPR_(蜡)〜(组织)值是0.935-0.945,而SPR_(水)〜(组织)值是0.990〜0.991。如果将蜡推注作为12 MeV射线的组织,则推注正下方的组织剂量要高估最大剂量的约2.5%(3厘米推注厚度)。对于15 MeV光束,误差约为1.4%。依次使用蜡和软组织作为推注材料模拟了左胸壁电子治疗案例。如果在推注剂量计算中将推注材料误分配为组织,则在MC模拟中会观察到剂量差异。但是,该错误主要在临床耐受范围内,尤其是对于在实践中更容易遇到的细小推注区域。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号