In this study, alternating voltages with different values were employed to study the behavior of Ar mixed with SF6. The percentage of SF6 in Ar was varied from 5% to 90% at a total gas pressure of 50 kPa, 100 kPa, 150 kPa and 200 kPa, and the breakdown voltages of each gas mixture were recorded. Similar to earlier studies under static electric fields and impulse fields, it is observed that the breakdown strength of Ar has increased dramatically when mixed with a small percentage of SF6 under alternating voltages. However, the breakdown voltages did increase monotonically, but not dramatically for higher SF6 concentrations in Ar.
机译:在这项研究中,采用不同值的交流电压来研究Ar与SF 6 混合的行为。在总气压分别为50 kPa,100 kPa,150 kPa和200 kPa的Ar中,SF 6 在Ar中的百分比从5%变为90%,并记录了每种气体混合物的击穿电压。与早期在静电场和脉冲场下的研究相似,可以观察到,在交流电压下,与少量SF 6 混合时,Ar的击穿强度急剧增加。然而,击穿电压的确单调增加,但是对于Ar中较高的SF 6 浓度而言,击穿电压并没有明显增加。