Research on Rapid Detection Technology for Running Safety of Heating Furnace

机译:加热炉运行安全快速检测技术研究

获取原文

摘要

Various defects encountered during the run of industrial heating furnace often can lead to the destruction of heating furnace and death of human beings, bring about serious safety accidents, In order to ensure the running safety of heating furnace, it is very necessary for detecting the thickness of heating furnace wall. This paper introduced the basic principle and structure of Rapid Detection System (RDS) of burning loss of heating furnace wall, and described the method of programming the BLPTAS(Burning Loss Percent Test and Analysis Software). By the experiment under two working conditions at the furnace chamber temperature of 600°C and 1000°C, its detection accuracy can be within 2%, meet the practice demands of rapid detection. Test data about burning loss of the furnace wall can be accurately provided, and analysis, expert-level evaluation and instruction also can be obtained by use of this technology, so as to minimize safety hazards and ensure the safe run of heating furnace.
机译:工业加热炉运行过程中遇到的各种缺陷,经常会导致加热炉的破坏和人员死亡,带来严重的安全事故,为保证加热炉的运行安全,检测厚度是非常必要的。加热炉壁。介绍了加热炉壁烧损快速检测系统(RDS)的基本原理和结构,并介绍了烧损率测试分析软件BLPTAS的编程方法。通过在600℃和1000℃炉膛温度两个工作条件下的实验,其检测精度可以在2%以内,满足快速检测的实际需求。利用该技术可以准确提供炉壁燃烧损失的测试数据,并进行分析,专家级评估和指导,以最大程度地减少安全隐患,确保加热炉的安全运行。