摘要

Beishan pumped storage station is located among several existing important buildings, such as main dam, the first and second-stage powerhouse, switch-station and high voltage lines etc. And its construction schedule was urgent. Based on analyzing the vibration mechanism of the buildings and adopting with explosive loading structure and priming network, a series of blasting vibration tests were carried out at traffic cavity, underground powerhouse, water conveying tunnel, washing pool behind main dam and so on, some of which were carried out on the condition of the powerplants running and corporating into the network. The permission vertical velocity index of master control room and powerplant's protection screens was increased from 0.50cm/s to 1.00cm/s, which greatly boosted the construction efficiency. Meanwhile, an on-line blasting vibration monitoring system was established, and run normally in more than 3 months,and abnormal sign was not found on the main monitor indicators of main dam, the powerplants run safely too.
机译:北山抽水蓄能电站座落在现有的几座重要建筑物中,例如大坝,一级和二级电站,开关站和高压线路等,其建设进度很紧迫。在分析建筑物的振动机理的基础上,采用爆炸物加载结构和引爆网络,对交通洞,地下厂房,输水隧洞,主坝后洗水池等进行了一系列爆破振动试验。这是在动力装置运行并整合到电网中的条件下进行的。主控室和电厂防护屏的允许垂直速度指标从0.50cm / s增加到1.00cm / s,大大提高了施工效率。同时,建立了在线爆破振动监测系统,并在3个月以上正常运行,在大坝主监测指标上未发现异常迹象,电厂也安全运行。