首页> 外文会议>Intelligent Control. 2003 IEEE International Symposium on >Fault detection and isolation based on Takagi-Sugeno modelling
【24h】

Fault detection and isolation based on Takagi-Sugeno modelling

机译:基于Takagi-Sugeno建模的故障检测与隔离

获取原文

摘要

One of the difficulties to detect and isolate faults in nonlinear systems via observer-based methods is the design of a residual generator. In this work a procedure to approach the fault detection and isolation problem in nonlinear systems is proposed. The result is obtained by deriving several subsystems, each subsystem containing information about specific faults, from the plant under consideration. Takagi-Sugeno modelling is used to design fuzzy observers and generate residuals. The detection and isolation task is solved by evaluating these residuals. The advantage of the proposed approach is that the design condition for the observers is relaxed. Furthermore the potential use of decoupling techniques is reinforced. The design methodology is shown using a laboratory three tank system.
机译:通过基于观察者的方法检测和隔离非线性系统中的故障的困难之一是残差发生器的设计。在这项工作中,提出了一种解决非线性系统故障检测和隔离问题的方法。通过从正在考虑的工厂中派生几个子系统来获得结果,每个子系统都包含有关特定故障的信息。 Takagi-Sugeno建模用于设计模糊观测器并生成残差。通过评估这些残差可以解决检测和隔离任务。所提出的方法的优点是放宽了观察者的设计条件。此外,去耦技术的潜在用途得到了加强。使用实验室三缸系统显示了设计方法。