首页> 外文会议>International Symposium on Computational Intelligence and Design >Reliability Research on Airborne Dual Redundancy of Electrical Wiring Interconnection System
【24h】

Reliability Research on Airborne Dual Redundancy of Electrical Wiring Interconnection System

机译:电气互连系统机载双冗余的可靠性研究

获取原文

摘要

To optimize airborne EWIS redundancy design, failure tree method was applied to analyze the reliability of parallel-series system and series-parallel system. Multi-random variable “minimization maximum” and “maximization minimum” methods were applied to analyze the EWIS cumulative distribution function. When the life span cumulative distribution function of functional module was known, the redundancy systems life span cumulative distribution function were reduced. If electrical wire life span was from exponential distribution, the simulation calculation results indicated: the reliability of parallel-series system was better than series-parallel system; the longer the systems worked, the larger the margin was. The research results are meaningful for airborne EWIS redundancy design.
机译:为了优化机载EWIS冗余设计,采用故障树方法分析了并联系统和串并联系统的可靠性。应用多变量“最大最小值”和“最小最小值”方法分析EWIS累积分布函数。当已知功能模块的寿命累积分布函数时,冗余系统的寿命累积分布函数会减少。如果电线的寿命是指数分布的,则仿真计算结果表明:并联系统的可靠性优于串联-并联系统。系统工作的时间越长,利润就越大。研究结果对机载EWIS冗余设计具有重要意义。