In this work, thermoelastic damping (TED) effect of diaphragm perforation on a hemispherical resonator is investigated, and is experimentally shown to improve the quality factor of the resonator. Specifically, this paper reports the quality factor improvement of a very high Q hemispherical resonator gyroscope (HRG) through making a hole on the micromachined HRG's shell. A hole (200µm in diameter) at the apex of a hemispherical shell (600µm in diameter) increases the Q and thereby ring down time by more than 50% and 100% experimentally and theoretically, respectively, for the HRG at an n=2 resonant frequency of 170kHz. Adding such a hole increases the resonant frequency only a few percent.
机译:在这项工作中,对半球形谐振器上的膜片穿孔的热弹性阻尼(TED)效应进行了研究,并通过实验证明可以提高谐振器的品质因数。具体而言,本文报告了通过在微机械加工的HRG壳体上打孔,提高了Q高的半球形谐振器陀螺仪(HRG)的品质因数。对于半球壳(直径为600μm)的顶点处的一个孔(直径为200μm),增加Q值,从而在n = 2共振时,HRG的实验和理论上的振铃时间分别超过50%和100%。频率为170kHz。添加这样的孔只会使谐振频率提高百分之几。