Power QFN device had CSR(Current Sense Ratio-Mirror cell Mosfet current to Main mosfet current Ratio. Mirror cell current is proportional to main mosfet, used for monitor main mosfet current) issue on TC500 or application. Failure analysis verified that it was caused by bump ball lift issue. XPS (X-ray Photoelectron Spectroscopy) Analysis verified the pad contamination caused the bump ball lift issue. After further analysis, the contamination was from solder paste out-gassing during Die bonding process. Finally, the contamination was reduced by die bond oven improvement and forming gas/exhaust parameters optimization and passed all reliability test.
机译:功率QFN器件在TC500或应用中出现了CSR(电流感应比-镜单元Mosfet电流与主MOSFET电流之比。镜单元电流与主mosfet成正比,用于监视主MOSFET电流)。故障分析证实,这是由撞球提升问题引起的。 XPS(X射线光电子能谱)分析验证了焊盘污染引起的凸起球抬起问题。经过进一步分析后,污染是由于芯片键合过程中焊锡膏放气所致。最后,通过改进芯片键合炉和优化成型气/排气参数减少了污染,并通过了所有可靠性测试。