首页> 外文会议>Annual International Conference of the IEEE Engineering in Medicine and Biology Society >A ROIC for Mn(TPP)Cl-DOP-THF-Polyhema PVC Membrane Modified n-Channel Si3N4 ISFET Sensitive to Histamine
【24h】

A ROIC for Mn(TPP)Cl-DOP-THF-Polyhema PVC Membrane Modified n-Channel Si3N4 ISFET Sensitive to Histamine

机译:用于Mn(TPP)的ROIC(TPP)CL-DOP-THF-POLYHEMA PVC膜改性N沟道SI3N4敏感的组胺敏感

获取原文

摘要

Intolerance of histamine could lead to scombroid poisoning with fatal consequences. Current detection methods for histamine are wet laboratory techniques which employ expensive equipment that depends on skills of seasoned technicians and produces delayed test analysis result. Previous works from our group has established that ISFETs can be adapted for detecting histamine with the use of a novel membrane. However, work to integrate ISFETs with a readout interfacing circuit (ROIC) circuit to display the histamine concentration has not been reported so far. This paper concerns the development of a ROIC specifically to integrate with a Mn(TPP)Cl-DOP-THF-Polyhema PVC membrane modified n-channel Si3N4 ISFET to display the histamine concentration. It embodies the design of constant voltage constant current (CVCC) circuit, amplification circuit and micro-controller based display circuit. A DC millivolt source is used to substitute the membrane modified ISFET as preliminary work. Input is histamine concentration corresponding to the safety level designated by the Food and Drugs Administration (FDA). Results show the CVCC circuit makes the output follows the input and keeps VDS constant. The amplification circuit amplifies the output from the CVCC circuit to the range 2.406-4.888V to integrate with the microcontroller, which is programmed to classify and display the histamine safety level and its corresponding voltage on a LCD panel. The ROIC could be used to produce direct output voltages corresponding to histamine concentrations, for in-situ applications.
机译:组胺的不耐受可能导致与致命后果的微谱中毒。用于组胺的电流检测方法是湿的实验室技术,采用昂贵的设备,这取决于经验丰富的技术人员技能,并产生延迟的测试分析结果。我们组的以前的作品已经确定ISFET可以适用于使用新型膜来检测组胺。然而,到目前为止,还可以使用读出接口电路(ROIC)电路进行整合的ISFET,以显示组胺浓度。本文涉及专门于与Mn(TPP)CL-DOP-THF-Polyhema PVC膜改性的N沟道Si3N4 IsFET集成的ROIC的开发,以显示组胺浓度。它体现了恒压恒流(CVCC)电路,放大电路和基于微控制器的显示电路的设计。 DC毫伏源用于将膜改性的ISFET替代为初步工作。输入是对应于食品和药物给药(FDA)指定的安全水平的组胺浓度。结果显示CVCC电路使输出跟随输入并保持VDS常数。放大电路将来自CVCC电路的输出放大到2.406-4.88V的范围,以与微控制器集成,这被编程为分类和显示LCD面板上的组胺安全电平及其对应电压。 ROIC可用于产生与组胺浓度相对应的直接输出电压,用于原位应用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号