首页> 外文会议>Annual conference of the International Society of Exposure Science >Model selection(absolute humidity and relative humidity) and Akaike's information criterion(AIC): Association between humidity and asthma admission
【24h】

Model selection(absolute humidity and relative humidity) and Akaike's information criterion(AIC): Association between humidity and asthma admission

机译:模型选择(绝对湿度和相对湿度)和赤池信息准则(AIC):湿度与哮喘发作之间的关联

获取原文

摘要

Background- There are published many studies of humidity effect on health condition. Humidity condition affects severity of asthma symptom. When studying association between humidity and health outcomes, we more use relative humidity than absolute humidity. We need to examine validity of humidity indicators. Aims-This study are to examine validity of using humidity indicator about association between humidity and health conditions Methods-We used the generalized additive model (GAM) to analyze data which is daily weather and asthma admission in Korea from 2003 to 2006 for humidity effect on asthma. Using asthma admission data of 6 cities, we analyzed to change humidity indicators absolute humidity and relative humidity respectively after controlling air pollution condition, temperature. Calculating moving average each of variables we controlled lag effect. Results-Among 6 cities, Seoul and Kwangju cities did not show significant results about humidity effect on asthma admission. In Busan and Incheon cities, AIC was calculated in the model with absolute humidity is lower 12176.87 (RR: 0.9398 95% CI : 0.9023-0.9788), 9234.068 (RR :0.9064, 95% CI: 0.8468-0.9701) respectively than that of using relative humidity. On the other hand, Daegu and Daejeon is shown higher AIC in model with using absolute humidity that of relative humidity model. AIC of Daegu and Daejeon cities are 9064.49 (RR: 0.9577, 95% CI: 0.9381-0.9776), 7668.60 (RR: 0.9479, 95% CI: 0.9208-0.9759) in relative humidity model. Conclusions-This study did not show evidence to select which humidity indicator clearly. However Busan and Incheon Cities showed lower AIC in absolute humidity model whereas AIC of Daegu and Daejeon was lower in relative humidity model. Salient different of these cities is founded geographical position. Busan and Incheon city is closer coast. On the contrary, Daegu and Daejeon city is inland city.
机译:背景技术-已经发表了许多关于湿度对健康状况影响的研究。湿度条件会影响哮喘症状的严重程度。在研究湿度与健康结果之间的关联时,我们更多地使用相对湿度,而不是绝对湿度。我们需要检查湿度指示器的有效性。目的-这项研究旨在检验使用湿度指示符来了解湿度与健康状况之间关系的有效性。方法-我们使用广义加性模型(GAM)分析了2003年至2006年韩国每天天气和哮喘住院情况对湿度影响的数据。哮喘。利用6个城市的哮喘住院数据,我们分析了控制空气污染状况,温度后分别改变湿度指标的绝对湿度和相对湿度。计算均线的变量我们控制了滞后效应。结果-在首尔市和光州市等6个城市中,湿度对哮喘住院率没有显着影响。在釜山和仁川市,模型中的AIC计算为绝对湿度低于使用的绝对湿度为12176.87(RR:0.9398 95%CI:0.9023-0.9788),923.068(RR:0.9064,95%CI:0.8468-0.9701)相对湿度。另一方面,在使用绝对湿度的模型中,使用相对湿度模型时,大邱和大田的AIC更高。在相对湿度模型中,大邱市和大田市的AIC为9064.49(RR:0.9577,95%CI:0.9381-0.9776),7668.60(RR:0.9479,95%CI:0.9208-0.9759)。结论-该研究没有显示证据明确选择哪种湿度指示剂。但是,釜山市和仁川市的绝对湿度模型中的AIC较低,而大邱和大田的AIC相对湿度模型中的AIC较低。这些城市的显着不同是建立地理位置。釜山和仁川市离海岸较近。相反,大邱市和大田市是内陆城市。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号