Long-Term Monitoring of FRP-Concrete Composite Bridge Deck for Cable-Stayed Bridges Using Optical Fiber Sensors

机译:使用光纤传感器对斜拉桥的FRP混凝土组合桥面进行长期监测

获取原文

摘要

The Korea Institute of Construction Technology has developed a precast FRP-concrete composite deck to be applied to cable-stayed bridges. This deck is a precast structural system in which concrete is disposed at the upper part and a hollow FRP tube is disposed at the bottom to play the role of tensile reinforcement and form. This paper presents the prototype of the so-developed FRP-concrete composite deck fabricated for trial construction. Electrical resistance sensors and optical fiber sensors were installed on the prototype to evaluate its structural stability and serviceability during the 17 months of operation through a series of field loading tests. From the field loading test results, the FRP-concrete composite deck was verified to secure sufficient structural stability and serviceability along the 17 months of operation even after the repeated passage of the heavy construction trucks. Besides, it appeared also that, for long-term monitoring, the optical fiber sensor provided more reliable measurement than the electrical resistance sensor glued to the structure.
机译:韩国建筑技术研究所开发了一种预制的FRP-混凝土复合甲板,可用于斜拉桥。该甲板是一个预制的结构系统,其中在上部放置混凝土,在下部放置空心FRP管,以起到抗拉和加固的作用。本文介绍了为试制而制造的这种经开发的FRP-混凝土复合甲板的原型。原型上安装了电阻传感器和光纤传感器,以通过一系列现场负载测试评估其在运行17个月期间的结构稳定性和可维修性。从现场载荷测试结果来看,FRP-混凝土复合甲板经过验证,即使在重型工程卡车反复通过后,也能确保在运行17个月期间具有足够的结构稳定性和可维护性。此外,对于长期监控而言,似乎光纤传感器比胶粘到该结构的电阻传感器提供了更可靠的测量。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号