A HEALTH CHECK OF THE ITALIAN SOLAR PHOTOVOLTAIC PARK USING SATELLITE-BASED SOLAR RESOURCE DATA

机译:意大利太阳能光伏公园使用基于卫星的太阳能资源数据的健康检查

获取原文

摘要

At country level, the average Performance Ratio PR for Italy is presently low (68.6% in 2016). At regional level we observe a strong dispersions in the results and the presence of some outliers. Regions with the lowest PR are Lombardia, Liguria, and Campania. Puglia, the region with largest average size of solar plants exhibits the highest PR. We then refine our analysis to province level calculating PR_(2016) values for the 108 Italian provinces using 2016 data, a year for which irradiation data are well aligned to long-term averages. With some outliers, the vast majority of PR_(2016) for the different provinces lies between 60-70%. We then look for some correlations that can describe the strong scatter in the data presented: (1) it is difficult to observe a clear correlation between average system size in the province and PR for average sizes below 45 kW. On the other hand, above this threshold, system size is generally a good indicator of good performance; (2) the residential (and building) density in the province (which can be correlated to some extent to increased shading losses, particularly for small/medium-size rooftop installations) has a strong impact on PR and can be described by a hyperbolic relation; (3) the effect of province elevation on PR is not clear, nevertheless, not necessarily provinces located at higher altitudes (and potentially increasingly affected by far shading) have lower PRs. These correlations are sometimes weak, but we believe that this analysis could be improved considerably by increasing the spatial granularity of the data and focusing on smaller geographical units, such as communes or even at the scale of the single PV plant.
机译:在国家一级,意大利的平均绩效比率公关目前低(2016年68.6%)。在区域一级,我们观察结果的强大分散和一些异常值。最低PR的地区是Lombardia,Liguria和Campania。普利亚,太阳能厂平均大小的地区显示出最高的PR。然后,我们将我们的分析恢复到省级计算PR_(2016)使用2016年数据的108个意大利省份的价值,辐照数据与长期平均值良好对齐。随着一些异常值,不同省份的绝大多数PR_(2016)位于60-70%之间。然后,我们寻找一些可以描述所提供数据中的强散射的一些相关性:(1)难以观察到该省的平均系统大小与PR平均尺寸低于45 kW的PR之间的明确相关性。另一方面,高于此阈值,系统尺寸通常是良好性能的良好指标; (2)该省的住宅(和建筑)密度(可以在一定程度上相关到增加阴影损失,特别是对于小/中等屋顶装置)对PR产生强烈影响,可以通过双曲线关系来描述; (3)Provie ovation对PR的效果尚不清楚,不一定不一定位于较高海拔(并且可能越来越多地受到远遮阳的影响)的省份具有较低的PRS。这些相关性有时是薄弱的,但我们认为可以通过增加数据的空间粒度并专注于较小的地理单元,例如包括在单个光伏厂的规模的较小地理单元上来显着提高该分析。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号