In this paper, we present our experimentalfindings for the forced-convective condensation of pure steamand ammoniasleam vapor mixture in a horizontal annulus in acountercurrent shell-tube condenser. Experiments withammonia-steam mixtures were conducted for 90 percentammonia concentration (by wt.) for vapor inlet mass fluxesranging from 2 to 5 kg/m~2s. The local heat transfercoefficient varied considerably along the condenser and thisvariation was strongly linked to the condensate flow patterns inthe annulus. Based on a condensate drainage model, the flow inthe annulus was mapped on to flow maps for horizontal in-tubecondensing flows. The delineated flow regimes were utilized toexplain augmentation or deterioration of local heat transfer inthe condenser. The average heat transfer coefficients arepresented as a function of the condensate and vapor Reynoldsnumber for both steam and ammonia-steam mixture. Theresults for pure steam are higher than those predicted byannular flow correlation developed in the past. For ammonia-steam mixtures, the average heat transfer coefficients are about16 percent of those for pure steam due to the vapor layerresistance at the interface.
机译:在本文中,我们展示了我们的实验研究,用于纯Steam和氨基蒸气混合物在ArounterCurrent壳 - 管冷凝器中的水平环空中的强制性对流凝结。实验含有含有90百分之醇浓度(通过重量)的蒸汽入口质量型从2至5kg / m〜2s的蒸汽入口质量散热。局部热传递沿冷凝器随着冷凝器的显着变化,并且该变化与凝结物流动图案的沉降液相连。基于冷凝水排水模型,将流动的流动映射到水平in-the-endensing流程的流程图。将划清的流动制度用于映射增强或局部热转印的劣化。作为蒸汽和氨 - 蒸汽混合物的冷凝物和蒸气ReynoldSnumber的函数,平均传热系数被呈现。纯蒸汽的结果高于过去开发的预测的受到预测的流量相关性。对于氨 - 蒸汽混合物,由于界面处的蒸汽层板,平均传热系数为纯蒸汽的约16%。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号