This paper presents a new innovative method for sensorless rotor position estimation at standstill for high speed PMSM. To avoid critical thermal losses in the high speed PMSM a controlled LC filter is connected between the machine and the inverter. This additional filter leads to failure of many known methods for sensorless rotor position detection at standstill. The presented method is suitable for accurate and reliable detection of the rotor position at standstill. The function principle is based on voltage pulses applied on the LC filter and the high speed PMSM. Based on measured stator currents and voltages a special structure to model the system behavior and to calculate the actual rotor position is used. This allows a parameter insensitive operation. All theoretical proposals are proved by practical experiments.
机译:本文提出了一种用于高速PMSM静止状态下无传感器转子位置估计的创新方法。为了避免高速PMSM中的严重热损失,在机器和逆变器之间连接了一个受控LC滤波器。这种附加的过滤器导致许多已知的静止状态下无传感器转子位置检测方法的失败。所提出的方法适用于静止状态下转子位置的准确和可靠的检测。该功能原理基于施加在LC滤波器和高速PMSM上的电压脉冲。基于测得的定子电流和电压,使用一种特殊的结构来对系统行为进行建模并计算实际转子位置。这允许参数不敏感的操作。所有理论建议均通过实际实验证明。