Over Voltage Protection Device Based on Multi-strategy

机译:基于多策略的过压保护装置

获取原文
获取原文并翻译 | 示例

摘要

Strong electromagnetic interference occurs when the locomotive was running. Therefore, measurement errors resulted from interference exist when monitoring the rail potential only at single point. This will lead to misoperation of the protection device. An over voltage protection device based on multipoint and multi-strategy was designed. The mathematical model of rail potential distribution was built. Fuzzy neural network and multi-sensor monitoring technology were applied in this design. The emulation analysis demonstrated that the proposed device has better reliability and higher control accuracy than the single strategy approach.
机译:机车运行时会发生强烈的电磁干扰。因此,仅在单点监视轨道电位时,存在因干扰引起的测量误差。这将导致保护装置误操作。设计了一种基于多点多策略的过压保护装置。建立了轨道电势分布的数学模型。本设计应用了模糊神经网络和多传感器监测技术。仿真分析表明,与单策略方法相比,该装置具有更高的可靠性和更高的控制精度。